These points aim to provide practical and relevant information for users implementing FrameworX in a security-conscious environment.
Introduction to IEC 62443
Brief overview of the IEC 62443 series of standards and its importance for securing Industrial Automation and Control Systems (IACS).
Explanation of the core concepts, such as Security Levels (SL), Zones, and Conduits.
FrameworX Architecture and IEC 62443 Alignment
Discussion on how FrameworX’s architecture and features inherently support the implementation of a secure environment according to IEC 62443 principles.
Mapping of FrameworX components to a typical Zones and Conduits model.
Implementing Foundational Requirements (FRs) with FrameworX
Practical guidance on how to use FrameworX features to meet the seven Foundational Requirements of the standard:
Identification and Authentication Control (IAC): Configuring users, groups, and security policies.
Use Control (UC): Setting up access permissions and privileges for different roles.
System Integrity (SI): Utilizing features like encrypted communication and system diagnostics.
Data Confidentiality (DC): Implementing secure data transmission with HTTPS, SSL, and VPNs.
Restricted Data Flow (RDF): Configuring firewalls and managing data flow between security zones.
Timely Response to Events (TRE): Using the logging, auditing, and alarm features to monitor security events.
Resource Availability (RA): Implementing redundancy and failover configurations.
Secure Deployment Guide
A checklist or best-practices guide for deploying a FrameworX solution in a way that aligns with IEC 62443.
Example reference architectures for common deployment patterns.
Further Resources
Links to official IEC 62443 documentation and relevant industry white papers.
What is IEC 62443 (scope & who should read)
Series overview (1-1 terms; 2-1/2-4 org/process; 3-2 risk/zone-conduit; 3-3 system SR/SL; 4-1/4-2 product & component).
Target roles: architects, integrators, IT/OT security, operations leads.
Core concepts
Zones & conduits; defense-in-depth; Security Levels (SL-T 1–4).
Foundational Requirements (FR1–FR7): Identification & Authentication, Use Control, System Integrity, Data Confidentiality, Restricted Data Flow, Timely Response to Events, Resource Availability.
Mapping to FrameworX features (control-by-control)
Identification & Authentication / Use Control: Security module (users, roles, policies), AD/LDAP integration.
Restricted Data Flow / Data Confidentiality: HTTPS/SSL, Secure Multi-Port Gateway, segmented client access.
Timely Response / Auditability: Alarms & notifications; Audit Trail usage.
Resource Availability: Redundancy configuration; Runtime/System Monitor; failover checks.
Architecture patterns aligned to IEC 62443
Purdue L1–L4 zoneing notes; place servers/clients; DMZ/edge patterns.
Examples: Standalone, Distributed, Cloud/Hybrid, Hot-Standby.
Implementation checklist (link out to How-to pages)
Asset inventory → risk & SL-T per zone → zone & conduit diagram.
Configure authN/authZ (roles/permissions, AD/LDAP).
Harden comms & endpoints (HTTPS/SSL, multi-port gateway; close unused ports).
Logging & audit (Audit Trail) and time sync.
Availability: redundancy, backup/restore, drills; document evidence.
SBOM & hardening references.
Evidence & testing
Map tests to FR/SL controls; link to Diagnostics/Performance tools for verification.
Related pages
Security Module, Runtime Users, AD/LDAP; Secure Multi-Port Gateway; HTTPS/SSL access; Redundancy; Diagnostics & System Monitor; Audit Trail.
Optional sibling (if you want a short concept too)
IEC 62443 for FrameworX Architects (Concepts) — a 1-page primer that points to the Reference above and to the How-to Guides (zone & conduit, hardening, redundancy). This keeps the taxonomy pure while giving newcomers an easy entry point.
IEC 62443 Cybersecurity Implementation
Overview
IEC 62443 provides a comprehensive framework for securing industrial automation and control systems (IACS). This guide helps implement IEC 62443 standards within FrameworX solutions, ensuring robust cybersecurity across all operational technology environments.
Quick Reference
- Standard Scope: Industrial automation and control systems security
- Security Levels: SL1 (Protection against casual violations) through SL4 (Protection against intentional, sophisticated attacks)
- Key Components: Policies, Procedures, System Requirements, Component Requirements
- FrameworX Compliance: Built-in features supporting zones, conduits, and security level implementation
1. Security Level Assessment
Determining Target Security Levels
- SL1 - Basic Protection
- Casual or coincidental violations
- No specialized knowledge required
- FrameworX features: Basic authentication, access logs
- SL2 - Cyber Security Protection
- Intentional violations using simple means
- Low resources, generic skills
- FrameworX features: Role-based access, encrypted communications
- SL3 - Advanced Protection
- Intentional violations using sophisticated means
- Moderate resources, IACS-specific skills
- FrameworX features: Multi-factor authentication, detailed audit trails
- SL4 - Maximum Protection
- Intentional violations using sophisticated means with extended resources
- FrameworX features: Hardware security modules, advanced cryptography
Risk Assessment Checklist
- [ ] Identify critical assets and processes
- [ ] Evaluate potential threat sources
- [ ] Determine consequence severity
- [ ] Calculate likelihood of occurrence
- [ ] Map to appropriate security levels
2. Zone and Conduit Architecture
Zone Definition in FrameworX
- Level 0-1: Process Control
- Direct I/O connections
- Real-time control networks
- Configuration: Isolated VLAN, no direct internet access
- Level 2: Supervisory Control
- SCADA servers
- Historian databases
- Configuration: DMZ between Level 1 and Level 3
- Level 3: Operations Management
- MES integration
- Production scheduling
- Configuration: Controlled access from enterprise network
- Level 4-5: Enterprise
- Business systems
- Cloud connectivity
- Configuration: Standard IT security policies
Conduit Security Implementation
- Data Diodes: Unidirectional data flow configuration
- Protocol Filtering: MQTT, OPC UA security profiles
- Access Control Lists: Tag-level permissions
- Encryption: TLS 1.3 for all inter-zone communications
3. Technical Security Controls
Authentication and Authorization
User Management
- Central authentication via Active Directory/LDAP
- Local fallback accounts for emergency access
- Password complexity requirements per SL level
- Session timeout configuration
Role-Based Access Control
- Operator roles with read-only access
- Engineer roles with configuration permissions
- Administrator roles with full system access
- Audit roles for security monitoring
Network Security Configuration
Firewall Rules
Level 0-1 → Level 2: Allow OPC UA (port 4840), Modbus TCP (502) Level 2 → Level 3: Allow HTTPS (443), SQL (1433) Level 3 → Level 4: Allow REST API (443), MQTT (8883) Default: Deny all
Network Segmentation
- VLAN configuration per zone
- Network address translation between zones
- Intrusion detection system placement
- Security monitoring points
Data Protection
Encryption Standards
- Data at rest: AES-256
- Data in transit: TLS 1.3
- Key management procedures
- Certificate lifecycle management
Backup and Recovery
- Automated configuration backups
- Encrypted backup storage
- Regular restoration testing
- Incident recovery procedures
4. Security Monitoring and Maintenance
Continuous Monitoring
Event Logging
- Authentication attempts
- Configuration changes
- System access patterns
- Anomaly detection alerts
Security Information and Event Management (SIEM)
- Log aggregation configuration
- Alert correlation rules
- Incident response triggers
- Compliance reporting
Patch Management
Update Procedures
- Monthly security patch assessment
- Test environment validation
- Maintenance window scheduling
- Rollback procedures
Vulnerability Management
- Quarterly vulnerability scans
- Annual penetration testing
- Risk assessment and mitigation
- Security advisory monitoring
5. Compliance Documentation
Required Documentation
Policies and Procedures
- [ ] Cybersecurity policy
- [ ] Incident response plan
- [ ] Change management procedures
- [ ] Access control procedures
System Documentation
- [ ] Network architecture diagrams
- [ ] Zone and conduit definitions
- [ ] Asset inventory
- [ ] Security control mapping
Evidence Collection
- [ ] Audit logs retention (minimum 90 days)
- [ ] Configuration baselines
- [ ] Security assessment reports
- [ ] Training records
Audit Preparation
Pre-Audit Checklist
- Review all security configurations
- Verify documentation currency
- Test incident response procedures
- Validate backup restoration
Common Audit Findings
- Incomplete network segmentation
- Missing security patches
- Inadequate access control
- Insufficient monitoring
6. FrameworX-Specific Implementation
Security Module Configuration
<SecurityConfiguration>
<ZoneDefinition level="2" name="SCADA">
<SecurityLevel target="SL3"/>
<Authentication type="MultiFactor"/>
<Encryption algorithm="AES-256"/>
</ZoneDefinition>
</SecurityConfiguration>
Secure Communication Setup
OPC UA Security
- Certificate generation and deployment
- Security policy selection (Basic256Sha256)
- User token configuration
- Secure discovery service
MQTT Security
- TLS certificate configuration
- Client authentication setup
- Topic-based access control
- Sparkplug B security considerations
Hardening Checklist
- [ ] Disable unnecessary services
- [ ] Remove default accounts
- [ ] Configure secure protocols only
- [ ] Enable audit logging
- [ ] Implement backup encryption
- [ ] Configure antivirus exclusions
- [ ] Set up security monitoring
- [ ] Document all deviations
7. Training and Awareness
Role-Based Training Requirements
- Operators: Security awareness, incident reporting
- Engineers: Secure configuration, change management
- Administrators: Full IEC 62443 implementation
- Management: Risk assessment, compliance requirements
Security Awareness Topics
- Password security and management
- Social engineering recognition
- Incident reporting procedures
- Physical security requirements
- Remote access policies
8. Incident Response
Response Procedures
- Detection and Analysis
- Alert verification
- Impact assessment
- Evidence collection
- Containment
- Isolate affected systems
- Preserve evidence
- Prevent spread
- Eradication and Recovery
- Remove threat
- Restore from backups
- Verify system integrity
- Post-Incident Review
- Root cause analysis
- Lessons learned
- Procedure updates
Emergency Contacts
- Internal security team
- FrameworX support
- External incident response
- Law enforcement (if required)