This document has only specific

information about

information about the device connection settings and its address syntax. 

Refer to the User Guide for more information on the Device Module.

On this page:

Table of Contents
maxLevel3
minLevel2
stylenone


Summary

Communication Driver Information

Driver name

TTS08

Assembly Name

T.ProtocolDriver.TTS08

Assembly Version

1.1.0.1

Available for Linux

False

Devices supported 

TTS08 family devices

Manufacturer

McCoy Global

Protocol

The SD50 is a TCPIP server that supplies a binary encoded sensor data stream on port 9876 and listens for parameter tare commands on port 9976

Interface

TCP/IP

PC Requirements

Ethernet port




Channels Configuration

Protocol Options

Not used in this driver.

Settings

  • AcceptUnsolicited must be checked.



Nodes Configuration

Station Configuration

Station syntax: <IP> ; <Port>

 Where:

  • <IP>: SD50 IP Address
  • <Port>:  9876 must be set to receive the data stream.



Points Configuration

Address

The syntax for the TTS08 communication points is: <SensorTxId>:<ItemID>

Where:

  • <SensorTxId>:  Sensor TxId in Hexa.  
  • <ItemID>: Specific item to be read, such as:
    • Battery
    • Pressure
    • Tension
    • Torque
    • Temperature
    • X_Axis_Acceleration
    • Y_Axis_Acceleration
    • Z_Axis_Acceleration
    • RPM



Driver Revision History