Note: If you have more than one channel, each must use a different port.

...

Node Configuration

Station syntax: <IP Address>;<Port>

Where:

  • <IP Address> = IP address of the device in the network
  • <Port> = Port of the device


...

Point Configuration

The syntax for the address is: <MID Name>


The possible MID values, for example, are presented in the table below:

...

WriteEventEnabled = true

WriteEvent = Changed


...

Communication

...

Flow

COMM_START

Before any other message is sent, this protocol requires a communication start message. Therefore, the use of the address "COMM_START" is mandatory.

...

For all other events, a subscription will be sent based on the configuration you specified in the Points table, targeting the corresponding MID. When the event occurs—such as a torque being applied by the tool—you will receive an unsolicited message with the relevant data.

...

Flow

All the logic for sending the "COMM_START" message first, then the subscription, and continuously sending "KEEP_ALIVE" messages is already handled by the protocol.