Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Alarms & Audit-Trail Tutorial teaches you to:

  • Create alarm groups and items
  • Configure alarm conditions
  • Set up notifications
  • Enable audit trail for FDA 21 CFR Part 11 compliance

Prerequisites:

In this page:

Table of Contents
maxLevel2
minLevel2
indent10px
excludeSteps
stylenone



Tutorial | Concept | How-to Guide | Reference

What You'll Learn


Create

alarm groups and items
  • Configure alarm conditions
  • Set up notifications
  • Enable audit trail
  • Step 1: Create

    Alarm Groups

    1. Navigate to Alarms → Groups
    2. Add Edit the groups:
    Critical
    Alarms:
    Name: Critical
    Warning
    • Priority: 1
    • Acknowledgment: Required
    Sound: Critical.wav
  • Color: Red
  • Warnings:

  • Name: Warnings
    • Priority: 3
    • Acknowledgment:
    Optional
    • not required 



  • Color: Yellow
  • Step 2:

    Define Alarm Items

    1. Go to Alarms → Items
    2. Create alarmalarms:
    High Temperature
    :
    Low Level
    Name
    • Tag: Tank1_
    HighTemp
    • Temperature
    • Group: Critical
    Tag: Tank1_Temperature
    • Condition: Greater than
    • Limit: 85
    • Message:
    "
    • Tank 1 temperature exceeds limit
    "
  • Deadband: 2
  • Low Level:

    Name:
    • Tag: Tank1_
    LowLevel
  • Tag: Tank1_Level
    • Level
    • Group:
    Warnings
    • Warning
    • Condition: Less than
    • Limit: 10
    • Message:
    "
    • Tank 1 level low
    "
    Step 3:

    Configure Deviation Alarms

    For rate-of-change monitoring:

    • Name: Pressure_Deviation
    • Type: Deviation
    • Tag: Line_Pressure
    • Setpoint Tag: Pressure_Setpoint
    • Deviation: ±10
    • Time: 60 seconds
    Step 4: Set Up Email Notifications
    1. Navigate to Alarms → Groups
    2. Select group → Email settings:
    Step 5:

    Configure Audit Trail

    1. Go to Alarms → Audit Trail
    2. Enable logging:
      • Login/Logout: Yes
      • Tag Changes: Yes
      • Alarm Acknowledgments: Yes
      • Configuration Changes: Yes
    3. Set storage:
      • Database: SQL Server
      • Table: AuditTrail
      • Retention: 365 days
    Step 6: Create
      • Alarm

    Areas

    For plant organization:

    1. Alarms → Areas
    2. Create hierarchy:
    Plant/
      ??? Production/
      ?   ??? Line1/
      ?   ??? Line2/
      ??? Utilities/
          ??? Boilers/
          ??? Compressors/
    1. Assign alarms to areas

    Step 7: Test Alarms

    1. Start Runtime
    2. Open Alarms → Online
    3. Force tag values to trigger alarms
    4. Verify:
      • Alarm appears in list
      • Color coding correct
      • Sound plays
      • Email sent
    Step 8: Alarm
      • Summary Display

        Create operator display:

        1. Displays → New
        2. Add AlarmViewer control
        3. Configure:
          • Show: Active alarms
          • Columns: Time, Area, Message, Value
          • Filter: By area or priority
          • Allow: Acknowledge, silence

    FDA 21 CFR Part 11 Setup

    For compliance:

    • Electronic signatures on acknowledgments
    • Audit trail cannot be disabled
    • User authentication required
    • Time synchronization enabled
    • Data integrity checksums

    Best Practices

    • Use consistent naming conventions
    • Set appropriate priorities (1-5)
    • Include clear messages
    • Test all alarm conditions
    • Document alarm philosophy
    • Regular alarm rationalization

    Next Steps

  • [Historian] - Store alarm history
  • [Reports Module] - Alarm reports
  • Test Alarms

    1. Start Runtime
    2. Open Alarms → Online
    3. Force tag values to trigger alarms
    4. Verify:
      • Alarm appears in list
      • Color coding correct
      • Sound plays
      • Email sent
    [Security Module] - User permissions

    In this section...

    Page Tree
    root@parent
    spaces93DRAF