Sector

Factory-Floor Interfaces

Group

Field Devices

ConnectorGenisys

and Microlok plusReliance CP3000

Name

GenisysReliance



Genisys devices

  • Name: Genisys Reliance
  • Version: 1.32.38.80
  • Protocol: Proprietary
  • Interface: TCP/IP Standard Serial Port
  • Runtime: .NET 24.0 8 (MultiplatformWindows)
  • Configuration:
    • Devices / Protocols

Table of Contents
maxLevel2
minLevel2
stylenone


Overview

Communication Driver Information

Driver name

Genisys

Reliance

Assembly Name

T.ProtocolDriver.

Genisys

Reliance

Assembly Version

1.

3

2.

3

8.

8

0

Available for Linux

False

Devices

supported 

supported

Genisys

CP3000

Manufacturer

Genisys

Protocol

Proprietary over TCP/IP

PC Requirements

Interface

Serial and MultiSerial

Serial port



Channels Configuration

Protocol Options

Not used in this driver.

Slave Mode

For Slave mode, the settings are configured as follows:

  • Server Mode: True
  • Accept Unsolicited: False
  • Port: Port configured in Master device.

Image Removed

Node Configuration

Station Configuration 

On the station configuration, there are the following parameters:

Image Removed

Where:

  • IP: IP Address.
  • Port: Port Number.
  • Slave ID: Slave ID in network.
  • Recall: Number of polls before a recall.
  • Secure Polls: Enable/Disable a CheckSum on the polls.

Master Mode

For Master Mode, all parameters must be configured.

Slave Mode

For Slave Mode, only IP and Slave ID parameters must be configured.

Point Configuration

Address

 The syntax for the Genisys communication point is:

  • Type: Indicator to Commands or Indications.
  • Address: Indicator to Commands or Indications

Image Removed

Write Group

When configuring the write address points, they must be in a WriteGroup since the communication always sends all 8 bits at once.

To configure the WriteGroup AccessType:

  1. Go to Devices → AccessTypes.
  2. Click Create New.
  3. Set a WriteTrigger to a Tag.

Image Removed

     5. After configuring the AccessType, go to Devices → Points.

     6. Set the Control points to the newly created AccessType.

Image Removed

Read Group - Slave Mode

When using the Genisys driver in Slave Mode, the Points must be configured for an AccessType with some specific configuration parameters.

To configure this AccessType:

  1. Go to Devices → AccessTypes.
  2. Click Create New. 
  3. Set ReadPolling to Never and check Read On Startup.

Image Removed

     4. After the configuration of the AccessType, go to Devices → Points.

     5.Set the Control points to the newly created AccessType.
  • CommunicationMode: 
    • SerCard: Serial communication through interface card.
    • Pt_to_Pt:Direct point-to-point communication.
  • SlaveId: Unique node identifier in the network (0-31).
  • Slot Source: Source slot position in the rack (0-126)
  • Protocol Processor:
    • Mono: Single processor - one CPU.
    • Multi: Multiple processor - multiple CPUs.



Nodes Configuration

Station Configuration 

PLCType:Set this field with the target PLC type. Available options are: A15, A20, A30, A30E, A40, A40E.

PLCStation: Identifies which station will be communicated with. Default value is 1.

SlotDest: Defines the communication moduledestination slot position in the Reliance rack. Default value is 0.

  • Serial channels:

Station syntax: <PLCType>;<PLCStation>;<SlotDest>

Ex: com1;A15;1;0

  • MultiSerial channels:

Station syntax: <ComPort>;<PLCType>;<PLCStation>;<SlotDest>

Where : <ComPort> = COM Port of the slave device in the network (default is com1).
Ex: com1;A15;1;0



Points Configuration

The syntax for the Reliance communication points is: <Command>:<Address>

Where:

  • <Command>: Represents the Command to execute:
    • Register: Read and write data registers.
    • NumberNodes: Sets the total number of nodes in the network.
    • Status: Monitors communication status.
  • <Address>: Address number

Driver Revision History

Reliance Driver

Driver Revision History

Genisys

Revision History

Version 

Notes

1.

3

2.

3

8.

8

0

Initial release on new documentation standards

.