Sector

Factory-Floor Interfaces

Group

Field Devices

ConnectorGenisys

and Microlok plusWDS DataStream

Name

GenisysWDSDataStream



Genisys devices

  • Name: Genisys WDSDataStream
  • Version: 12.30.30.80
  • Protocol: Proprietary
  • Interface: TCP/IP Standard Serial Port
  • Runtime: .NET 24.0 8 (MultiplatformWindows)
  • Configuration:
    • Devices / Protocols

Table of Contents
maxLevel2
minLevel2
stylenone


Overview

Communication Driver Information

Driver name

Genisys

WDSDataStream

Assembly Name

T.ProtocolDriver.

Genisys

WDSDataStream

Assembly Version

1

2.

3

0.

3

0.

8

0

Available for Linux

False

Devices supported 

Genisys

Manufacturer

Genisys

Protocol

Proprietary over TCP/IP

PC Requirements

Interface

Standard Serial Port

Serial port



Channels Configuration

Protocol Options

Not used in this driver.

Slave Mode

For Slave mode, the settings are configured as follows:

  • Server Mode: True
  • Accept Unsolicited: False
  • Port: Port configured in Master device.

Image Removed

BlockSize: Defines the maximum amount of items per group, the default value is 250.


Nodes

Node

Configuration

Station Configuration 

On the There is no station configuration , there are the following parameters:

Image Removed

Where:

  • IP: IP Address.
  • Port: Port Number.
  • Slave ID: Slave ID in network.
  • Recall: Number of polls before a recall.
  • Secure Polls: Enable/Disable a CheckSum on the polls.

Master Mode

For Master Mode, all parameters must be configured.

Slave Mode

For Slave Mode, only IP and Slave ID parameters must be configured.

for the WDSDataStream driver.



Points Configuration

Point Configuration

Address

 The syntax for the Genisys WDSDataStream communication point points is: <DataType>

  • Type: Indicator to Commands or Indications.
  • Address: Indicator to Commands or Indications

Image Removed

Write Group

When configuring the write address points, they must be in a WriteGroup since the communication always sends all 8 bits at once.

To configure the WriteGroup AccessType:

  1. Go to Devices → AccessTypes.
  2. Click Create New.
  3. Set a WriteTrigger to a Tag.

Image Removed

     5. After configuring the AccessType, go to Devices → Points.

     6. Set the Control points to the newly created AccessType.

Image Removed

Read Group - Slave Mode

When using the Genisys driver in Slave Mode, the Points must be configured for an AccessType with some specific configuration parameters.

To configure this AccessType:

  1. Go to Devices → AccessTypes.
  2. Click Create New. 
  3. Set ReadPolling to Never and check Read On Startup.

Image Removed

     4. After the configuration of the AccessType, go to Devices → Points.

     5.Set the Control points to the newly created AccessType.

Where:

  • <DataType>:

DataType

Batt

XVibration

YVibration

ZVibration

Pressure

Torque

Tension

Rpm

Timestamp



Driver Revision History

WDSDataStream Driver

Driver Revision History

Genisys

Revision History

Version 

Notes

1

2.

3

0.

3

0.

8

0

Initial release on new documentation standards

.