Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Image Modified Alarms Module

Overview 

The Alarms Module monitors and manages real-time alarm events, notifications, and audit trail information. It provides critical event alerting and stores data for compliance and future analysis.

Image Removed

Alarms Module links: How-to Guide, Reference 

Panel
borderWidth1
borderStylesolid
titleOn this Page:

Table of Contents
maxLevel2
minLevel2

Key Concepts

  • *AlarmItem*: Each tag monitored by the Alarm Module with defined limits and messages
  • *AlarmGroup*: Collection of AlarmItems sharing properties like acknowledgment requirements
  • *AlarmArea*: Hierarchical grouping for organizational structure
  • *Audit Trail*: Automatic logging of key system events and operator actions

(Concept) provides the critical event detection and notification layer for FrameworX solutions, enabling operators to respond quickly to abnormal conditions and maintain safe, efficient operations. 

Image Added

On this page:

Table of Contents
maxLevel2
minLevel2
indent10px
excludeSteps
stylenone




Alarms → Tutorial | Concept | How-to Guide | Reference



Understanding Alarms in Automation

Industrial processes require continuous monitoring to detect deviations from normal operation. The Alarms Module bridges the gap between raw sensor data and actionable operator responses by:

  • Condition Monitoring - Detect when process values exceed safe or optimal ranges
  • Event Notification - Alert operators through multiple channels
  • State Management - Track alarm lifecycle from detection to resolution
  • Compliance Recording - Maintain audit trails for regulatory requirements

Key Concepts

  • AlarmItem: Individual condition monitored for alarm generation based on tag values and defined limits
  • AlarmGroup: Collection of alarm items sharing common acknowledgment, notification, and logging behaviors
  • AlarmArea: Hierarchical organization structure for grouping alarms by location or function
  • AuditTrail: Chronological record of system events, operator actions, and alarm occurrences for compliance

What It Does

The Alarms Module provides comprehensive alarm management through:

  • Real-Time Evaluation - Continuously monitor tag values against configured conditions
  • Intelligent Notification - Multi-channel alerts via sound, visual, email, SMS, or custom methods
  • Acknowledgment Workflow - Require operator confirmation of critical alarms
  • Hierarchical Organization - Group alarms by area, system, or responsibility
  • Historical Logging - Record all alarm events for analysis and compliance
  • Deadband Management - Prevent alarm flooding through time and value hysteresis
  • Shift-Based Limits - Different alarm thresholds for different operational periods

What It Does

  • Monitors real-time tag values against defined limits
  • Triggers notifications via multiple channels (Display, SMS, Email)
  • Stores alarm history in any configured database
  • Organizes alarms in hierarchical groups and areas
  • Tracks operator actions and system events for compliance

Configuration Workflow

Alarms Module

Configuration Workflow

Select Define triggers, limits, and messagesSet logging behaviorDefine
StepActionDescription
Create AlarmItemsDefine conditions
Specify tags and limits to monitor
Configure AlarmGroups

Use predefined or create custom

Set behaviorsDefine
acknowledgment and
notification
Build AlarmAreas

Optional organization

Create hierarchical structure

Runtime Behavior

Monitoring and Evaluation

The module subscribes to all configured tags and evaluates alarm conditions on each value change. When conditions are met, alarms trigger according to their group settings.

Create hierarchyOrganize by plant structure
Set Global SettingsSystem configurationDatabase and audit trail setup

Runtime Behavior

Alarm States

The module manages alarms through defined state transitions:

  • Normal - No alarm condition exists
  • Active - Condition detected, awaiting acknowledgment
  • Acknowledged - Operator confirmed awareness
  • Normalized - Condition cleared, awaiting final acknowledgment

Notification Methods

Alarms trigger notifications based on group configuration:

  • Visual indicators on operator displays
  • Audible alerts with configurable sounds
  • Email and SMS through script integration
  • External system interfaces via custom methods

Performance Management

Built-in features prevent alarm system overload:

  • Deadbands prevent rapid re-triggering
  • Priority levels highlight critical conditions
  • Area filtering focuses operator attention
  • Acknowledgment requirements ensure awareness

Feature Highlights

  • Pre-Defined Groups - Critical, Warning, and AuditTrail groups ready to use
  • FDA Compliance - 21 CFR Part 11 audit trail capabilities
  • Flexible Database - Support for SQLite, SQL Server, PostgreSQL, and more
  • Runtime Control - Start, stop, pause alarm evaluation dynamically
  • Display Integration - AlarmViewer and AlarmArea controls for HMI
  • Script Integration - Custom notification methods via Script Classes
  • Distributed Architecture - Alarms evaluated centrally, viewed anywhere
  • Localization Support - Multi-language alarm messages and displays

In this section...

Page Tree
root@parent
spaces93DRAF

Visualization and Interaction

The AlarmViewer component displays real-time and historical alarms. Users can acknowledge, filter, and manage alarms through the interface.

Image Removed

Features Highlights

  • Real-time processing with millisecond timestamps
  • Dynamic multi-language message support
  • Store-and-forward archiving
  • Automated hot-standby replication
  • Custom notification channels
  • Hierarchical alarm management