This document has only the specific information about the device connection settings and its address syntax.

Refer to the User Guide for more information on the Device Module.

On this page:


Summary

Communication Driver Information
Driver nameCincinnati
Assembly NameT.ProtocolDriver.Cincinnati
Assembly Version1.1.0.0
Available for LinuxFalse
Devices supported 

Devices compatible with Sentinel I-28 precision leak test instrument.

ManufacturerCincinnati Test Systems
ProtocolProprietary
InterfaceRS232 or RS485
PC RequirementsSerial port

Channels Configuration

Protocol Options

Not used in this driver.

The remaining channel configurations are standard according the description on the reference guide.



Nodes Configuration

Station Configuration 

Not used in this driver.



Points Configuration

Address

The syntax for the Cincinnati communication point is: <Command>

  • <Command>: It indicates that this specific command is associated with the specific Tag Name.  


Command

Description

P01Time

Time of Test #1

P01Date

Date of Test #1

P01Leak

Leak of Test #1

P01Loss

Loss of Test #1

P02Time

Time of Test #2

P02Date

Date of Test #2

P02Leak

Leak of Test #2

P02Loss

Loss of Test #2

P03Time

Time of Test #3

P03Date

Date of Test #3

P03Leak

Leak of Test #3

P03Loss

Loss of Test #3

 


Driver Revision History


Cincinnati Revision History
Version Notes
1.1.0.0Initial release on new documentation standards