Introduction to Devices module

The Devices module implements real-item data communication with a wide variety of field devices and industrial protocols, supporting standard interfaces like OPC-UA, OPC-DA and MQTT and Hart.

The connectivity also includes IT protocols, like SNMP and Ping, and connection with Historian tools, such as OSIsoft PI, GE Historian, InfluxDB and Canary.

Currently over 50 drivers are included in the platform, and our development team has experience with more than 200 communication protocols.

On this page:


Purpose and Key Concepts

The Devices module facilitates seamless communication and data exchange with various field devices and industrial protocols, simplifying system architecture and enhancing connectivity. The configuration of the Devices module is performed on the sections:

Protocols

Protocols are the rules governing the communication between devices. Our software supports a variety of communication protocols.

Channels

Channels are created and configured to handle specific communication protocols and drivers. Each channel is defined by a specific protocol driver and connection type, such as RS-232 or TCP/IP. Channels allow the module to access multiple devices (such as PLCs) using the defined protocol and interface. The configuration of Channels is on the Solution Explorer, at Devices → Channels.

Nodes

Each device connected to the system through channels is called a Node. Nodes can be individual devices or groups of devices. Each node contains one or more Points. The configuration of Nodes is on the Solution Explorer, at Devices → Nodes.

Points

Points are individual items that can be read or written from/to nodes. They can be registers, I/O values, or variables residing in field devices (nodes). Each Point is bound to a specific Tag in the Solution configuration.

AccessType

Each Point is associated with an AccessType, which defines the rules for reading and/or writing values for that Point, such as the polling rate, whether a read is performed on startup, and whether you write values to that Point. The AccessType allows users to configure how clients can access data points in the system.


Understanding the Devices module

Feature Highlights

  • Simplify your architecture by removing the needing for additional communication products.

  • Easily setup a communications hub to support comms and logic between practically any device, any database, any historian, anywhere.

  • On-Premise, Edge or enterprise level, and to/from the cloud – we have you covered!

  • MQTT Broker and OPC Server are both built-in!

  • MQTT SparkPlug B and OPC-UA simulators expedite demos and prototyping.

  • Driver Toolkit allows our team, or any third-party, to easily add new interfaces.

Implementing Communication Protocols

Our software supports numerous communication protocols for HMI and industrial device interaction. The platform also supports open communication standards, like OPC, but there are various benefits in having the native protocol implementation. When using the platform, you don't need to understand the details of the protocol implementation because you can easily map the devices and the information you want to read or write from the device. However, if you want to have a deeper understanding of what a communication protocol is and how they are implemented in the system, you can refer to the page Protocols.

When using the Devices module, you can use multiple protocols simultaneously. The selection of the protocols is explained in Device Channels.

Handling Read And Write Events

In a SCADA system, handling read and write events is crucial for the efficient exchange of data between the HMI, PLCs, and other devices. Our software facilitates these events by allowing users to configure access types, which define the specific methods for reading and writing the values of each data point. The access types can be configured to determine the polling rate, specify whether a read is performed on startup, and decide whether unsolicited input is accepted.

The page Access Types Configuration has a detailed explanation of the concepts of development and execution of communication drivers.

Devices Module And ExternalTags Distinctions

While both Devices module and ExternalTags manage data points and their communication, the Devices module focuses on field device communication, whereas ExternalTags focuses on the overall management of tags within the platform environment.

Devices represent the physical equipment in the system, while ExternalTags are the logical entities that store and manage tag information. Understanding the distinction between these two components is essential for effective system configuration and management. By clearly separating the responsibilities of these components, our software promotes modularity, simplifies configuration, and enables users to build scalable and maintainable solutions.

You can see External TagProviders for more information.


Configuring the Devices module

In this section, we'll guide you through a quick Devices module configuration, including management of channels, nodes, and points, protocol gateway setup, and AccessType customization. To check out the full configuration, go to Device Channels.

Configuration Workflow

  • Select a communication protocol

  • Define device channels and their settings

  • Define nodes and stations

  • Add and edit device points

  • Customize pre-defined AccessTypes (if necessary)

Creating and Managing Channels

Device channels facilitate communication between the HMI and system devices. To efficiently create and manage these channels, adhere to the following process:

  • To create a new channel, navigate to Devices → Channels and click on "New Channel" Fill in the necessary information in the "Create New Channel" window and confirm by clicking "OK." The new channel will appear as a row in the table.

  • To edit existing channels, return to Devices → Channels. Customize the table by adding or removing columns through right-clicking the column heading area and selecting the desired columns. Modify the appropriate fields in the corresponding row to make adjustments to the channel.

To learn more about remote execution, see Remote Execution.

To learn more about Simulator Driver, explore TSimulator Auto Generated Values.

Defining Nodes and Stations

Configuring nodes involves defining devices or PLCs for network communication. To configure nodes, go to Devices → Nodes and input the required information. Columns can be added or removed by right-clicking the column heading area. Device node configuration properties include Name, Channel, PrimaryStation, BackupStation, SyncDate, SyncStation, SyncSettings, TemplateID and Description, each serving a specific purpose. For protocol-specific settings, consult the documentation Creating Nodes.

Adding and Editing Device Points

Adding and editing points involves configuring data points linked to nodes, which are accessible through tags. To configure data points, navigate to Devices → Points and input the required information. Columns can be added or removed by right-clicking the column heading area. Key device points configuration properties include TagName, Node, Address, DataType, Modifiers, AccessType, Scaling, TemplateID and Label. For protocol-specific settings, consult the documentation Adding and Editing Points.

Customizing Pre-defined AccessTypes

Customizing predefined AccessTypes allows users to optimize data exchange methods for reading and writing data point values. To configure AccessTypes, go to Devices → AccessTypes and either edit an existing access type by double-clicking a field or create a new one by clicking "New Item..." Input the required information. The OnDisplayOrServer AccessType efficiently reads data when used by the application. For more information, visit the OnDisplayOrServer AccessType section.

Tutorials

The Device Configuration Tutorial provides a detailed guide to configuring the Modbus interface, along with the essential concepts that apply to all communication drivers. This tutorial demonstrates how to define multiple protocol interfaces using the abstraction layers, such as Channels and Nodes, provided by the platform. You will learn the differences in syntax for the STATION and ADDRESS fields when using various protocols, as well as the configuration and testing procedures that remain consistent across all communication interfaces.

The tutorial includes an overview of device configuration features, which enable users to configure and manage industrial automation devices such as PLCs, HMIs, sensors, actuators, and others. It offers a user-friendly graphical interface for adding, removing, and configuring these devices in an automation solution. You will also explore how to configure communication parameters and tags for each device, ensuring reliable and accurate communication between devices and the automation control system.

For the Device Configuration Tutorial, take a look at the Tutorial: Modbus Configuration page.


Working with the Devices module

The Devices module is an essential component that enables seamless communication between the HMI and various devices in the industrial automation system, such as PLCs and other equipment. To maximize the potential of this module, it is crucial to understand its features and capabilities in-depth.

Simulator Drivers

The TSimulator driver is a communication protocol that allows users to generate random values in a variety of data types for testing and validation purposes. It is designed to be used with the Devices module and provides a set of flexible options that allow users to create accurate and customized simulations for their systems. TSimulator supports multiple data types, including BOOL, INTEGER, FLOAT, STRING, RAMP, and SINE. For each data type, the user can configure the minimum and maximum value that the simulation value can reach, as well as other options such as string length for the STRING type or ramp step for the RAMP type.

The TSimulator is an internal driver developed by Tatsoft, designed to work seamlessly with our software. In addition to the TSimulator, there are three external simulators available for integration with the platform. This makes a total of four simulators at your disposal:

  1. TSimulator (internal Tatsoft driver)

  2. OPC UA Simulator (external simulator)

  3. MQTTspB Simulator (external simulator)

  4. Modbus Protocol Simulator (external simulator)

For more information, see TSimulator Auto Generated Values.

Using Data Quality on Displays

Monitors can display and use the data quality on communication tags to ensure accurate and reliable information is being presented to operators.

Tooltip option

Data quality is a critical aspect of any HMI/SCADA system, our platform allows users to incorporate data quality on displays to provide a visual representation of data reliability, enabling operators to make well-informed decisions. This allows operators to identify potential issues and take appropriate action to maintain system performance and safety.


Troubleshooting and Best Practices

Built-in Diagnostics tools

There are three built-in Tools for diagnostics on software framework: PropertyWatch, TraceWindow and ModuleInformation.

For information on those tools in general go to Diagnostics Tools, for specific information on levering its usage on Devices module diagnostics go to Devices Monitor.

Common #Issues and Solutions

#ControlLogix PLC Type

In the PLC Address Import section under Devices → Points, it is important to ensure that the correct protocol option is selected when connecting ControlLogix PLCs. In some cases, the default option "Model OTHERS" may not work correctly, and it may be necessary to select a specific model, such as "Model 1756-L8X". If you encounter issues with a ControlLogix Channel not sending or receiving values, try changing the protocol option to the specific model and test the communication.

#ControlLogix Micro850

In the current version of the driver, specifically the Micro850 model (accessed in Devices → Channels → ProtocolOptions → Model), an error occurs when importing tags into the device node using the "From Device" option, which is expected due to the way the driver's API was implemented. We have a solution for this, which involves importing using the "From Filename" option. Our platform only accepts files in the .L5K format, in the case of .xlsx files or similar, it is necessary to open them in a table editor, make the necessary modifications, and export as .CSV, which can then be imported in Solution Settings → Import Tags → CSV File.

It's important to pay attention to the slots of the nodes because, depending on the configurations, it may only work with a specific slot depending on the physical architecture of how the PLC is set up, for example slot 2.

From there, simply configure to synchronize using the "From Filename" option, and the connection will function correctly.

#Importing L5K from ControlLogix

In the PLC Address Import section under Devices → Points, it is important to ensure that the path and file name are correct when importing L5K files using the "From Filename" or "From Device" options. In some cases, the "From Device" option may fail, and it may be necessary to use the "From Filename" option with the L5K file to make it work correctly.

#Performance:

Optimize the polling rates and access types for data points to reduce unnecessary data traffic and improve system performance. Use the OnDisplayOrServer AccessType for efficient data reading when the application is using the data.

Best Practices and #Recommendations

#System Design

Plan and design your industrial automation system with scalability and maintainability in mind. Use a modular approach, separating responsibilities between devices, ExternalTagss, and other modules. This promotes efficient workflows and simplifies system management.

#Documentation

Keep thorough documentation of your system, including device configurations, communication settings, and customizations. This will help with troubleshooting, maintenance, and future system upgrades.

#Recommendation -Training

Ensure that operators and maintenance personnel are well-trained in using platform and understand the specific configurations of your system. This will enable them to identify and resolve issues efficiently, minimizing system downtime.

#Regular Maintenance and Updates

Schedule regular maintenance for your system, including software updates, hardware inspections, and performance assessments. This proactive approach will help to identify potential issues before they escalate, ensuring the reliability and performance of your industrial automation system.


Device Runtime Attributes

Configure security attributes to protect critical data and ensure system integrity.

The Device namespace  is the entry point for all objects related to the Devices module. For general information on namespace and object concepts, go to the section Objects and Attributes.

The Device.Channel object lists all of the configured channels and their runtime properties.

The Device.Node object lists all of the configured nodes and their runtime properties.

The Device.AccessType object lists the defined access types and has options to execute synchronous calls on reading and writing to the device. 

The following tag properties are updated based on the Devices module:

Example
tag.tagName.DevicePointDevice point address connected with this tag.

See Namespaces Reference for the complete list of properties and available methods.