The Siemens TI505 driver implements communication with Simatic TI505 devices. For TCP/IP communication, the driver uses both CAMP and CAMP Packed Task Code messaging protocols for efficient data transfer.
Communication Driver Name: SimaticTI505
Current Version: 1.0.0.0
Implementation DLL: T.ProtocolDriver.SimaticTI505.dll
Protocol: CAMP and CAMP+Packed Task Code
Interface: TCP/IP
PLC types supported: Simatic TI505 and compatibles devices
Multi-threading: User configurable. Default is five threads to each network node
Max number of nodes: User defined
PC Hardware requirements: Standard PC Ethernet interface board
Supported Operands:
Data Type | Variables | Format | Read | Write |
---|---|---|---|---|
V | Memory | Short | Yes | Yes |
M | Memory | Short | Yes | Yes |
X | Discrete Input Packed | 16bits | Yes | Yes |
Y | Discrete Output Packed | 16bits | Yes | Yes |
C | Control Register Packed | 16bits | Yes | Yes |
WX | Word Input | Short | Yes | Yes |
WY | Word Output | Short | Yes | Yes |
TCP | Time/Counter Preset | Short | Yes | Yes |
TCC | Time/Counter Current | Short | Yes | Yes |
DSP | Drum Step Preset | Short | Yes | Yes |
DSC | Drum Step Current | Short | Yes | Yes |
DCP | Drum Count Preset | Short | Yes | Yes |
STW | System Status Word | 16bits | Yes | |
DCC | Drum Current Count | 32bits | Yes |
The driver supports the protocols below:
None
TCP/IP channels
NodeConnections: Defines the maximum number of parallel requests that will be sent to each node (asynchronous communication)
TCP/IP channels:
Station syntax: <IP address>;<Port>
Where:
E.g.: 192.168.1.101;1505
The syntax for the SiemensTI505 communication points is: <DataType><Address>
Where:
DataType | Variables |
---|---|
V | Memory |
M | Memory |
X | Discrete Input Packed |
Y | Discrete Output Packed |
C | Control Register Packed |
WX | Word Input |
WY | Word Output |
TCP | Time/Counter Preset |
TCC | Time/Counter Current |
DSP | Drum Step Preset |
DSC | Drum Step Current |
DCP | Drum Count Preset |
STW | System Status Word |
DCC | Drum Current Count |
For more information about the valid data type, see Supported Operands.
E.g.: V100 (DataType = V, Address = 100)
Note
For Floating Point format, select "Single DataType", and set the Modifiers column option for "WordSwap" to "True".
The status of the driver's execution can be observed through the diagnostic tools, which are:
• Trace window
• Property Watch
• Module Information
The above tools indicate if the operations have succeeded or have failed. A status of 0 (zero) means communication is successful. Negative values indicate internal driver errors, and positive values indicate protocol error codes.