Property

Value

Sector

Factory-Floor Interfaces

Group

Field Devices

Connector

TTS08 SD50 Server

Name

TTS08



TTS08 family devices

  • Name: TTS08
  • Version: 1.1.0.1
  • Protocol: Proprietary
  • Interface: TCP/IP
  • Runtime: .NET 2.0 (Multiplatform)
  • Configuration:
    • Devices / Protocols

On This Page:


Overview

Communication Driver Information

Driver name

TTS08

Assembly Name

T.ProtocolDriver.TTS08

Assembly Version

1.1.0.1

Available for Linux

False

Devices supported 

TTS08 family devices

Manufacturer

McCoy Global

Protocol

The SD50 is a TCPIP server that supplies a binary encoded sensor data stream on port 9876 and listens for parameter tare commands on port 9976

Interface

TCP/IP

PC Requirements

Ethernet port




Channel Configuration

Protocol Options

Not used in this driver.

Settings

  • AcceptUnsolicited must be checked.



Node Configuration

Station Configuration

Station syntax: <IP> ; <Port>

 Where:

  • <IP>: SD50 IP Address
  • <Port>:  9876 must be set to receive the data stream.



Points Configuration

Address

The syntax for the TTS08 communication points is: <SensorTxId>:<ItemID>

Where:

  • <SensorTxId>:  Sensor TxId in Hexa.  
  • <ItemID>: Specific item to be read, such as:
    • Battery
    • Pressure
    • Tension
    • Torque
    • Temperature
    • X_Axis_Acceleration
    • Y_Axis_Acceleration
    • Z_Axis_Acceleration
    • RPM



Driver Revision History

TTS08 Revision History

Version 

Notes

1.1.0.1

Initial release on new documentation standards.



In this section...