1. The Problem

The loading base facility needed a comprehensive system to manage and control the loading of diverse products (milk, chemicals, fuel, grains, etc.) across multiple loading bays. The facility lacked an integrated solution to automate access control, manage loading operations with precision, handle multi-compartment vehicles, and provide real-time operational data while maintaining seamless connectivity with the company's ERP system.

2. The Solution

The Loading Base Project was implemented with an integrated interface that manages all hardware, controls loading operations, and provides real-time data. The solution includes a WEB interface for registration and configuration of all process data and base customization.

The system automates the entire workflow: orders are inserted into the system, and from there, all access control and loading operations are automatic. When a truck driver arrives at the gate with a barcode tag, the system reads the information and directs them to one of 30 loading bays containing the required product. The system controls high-precision milliliter meters and manages multi-compartment tanker trucks, where each compartment can be filled with different products (gasoline, kerosene, etc.).

             [ERP System]
                     |
            [Application Server]
                     |
    ??????????????????????????????
    |                              |                         |                 
[DB Server]   [Primary Server]  [Backup Server]         
    |                              |                          |                 
    ??????????????????????????????
                     |
          [OPC Server → PI System]
                     |
        ???????????????????????????
        |                       |              |
  [NEXTO PLC]   [Presets]    [TEDs]
        |                       |              |
???????????????????????????
 |                           |                  |                      |               
 [30 Loading     [Flow      [Barcode          [5 Client          
    Bays]           Meters]    Readers]        Workstations]      


Technical Architecture:

3. Key Enablers

4. Results