--- title: "Acme Corp — Tag Naming and Structure Standards" tags: [naming, convention, tags, structure, standard, acme, company] description: "Acme Corp company standard for UNS tag naming, folder hierarchy, data types, and descriptions. Apply to all new Acme solutions." version: "2.1" author: "Acme Corp Engineering" --- |
Company-specific naming conventions for Acme Corp: mandatory 4-level tag hierarchy, imperial units, description format standards, and standard equipment tag templates. This is a user-created skill example showing how integrators enforce company standards. |
This is an example of a user-created skill. It shows how an integrator or end-user would create a company-specific skill to enforce their naming standards. To create your own, see the Skill Authoring Guide. |
|
Use this skill when:
All Acme tags follow this 4-level hierarchy:
{Site}/{Unit}/{Equipment}/{Measurement}
|
Examples:
Houston/Distillation/Column1/TemperatureHouston/Distillation/Column1/PressureHouston/Utilities/Boiler2/SteamFlowBaytown/Cracking/Reactor3/CatalystLevelRules:
Level | Description | Examples |
|---|---|---|
Site | City name | Houston, Baytown, Beaumont |
Unit | Process unit name | Distillation, Cracking, Utilities, Storage |
Equipment | Equipment ID with number suffix | Column1, Pump3, Boiler2 |
Measurement | What is measured | Temperature, Pressure, Level, Flow, Status, Speed |
Never use:
|
Measurement Type | DataType | Unit | Example |
|---|---|---|---|
Temperature | Double | °F | 350.5 |
Pressure | Double | PSI | 125.3 |
Level | Double | % | 67.2 |
Flow | Double | GPM | 1200.0 |
Speed | Double | RPM | 3600.0 |
Status | Integer | enum | 0=Off, 1=Running, 2=Fault |
Command | Boolean | — | True/False |
Setpoint | Double | same as measurement | 350.0 |
Important: Acme uses imperial units (°F, PSI, GPM), not metric. All tag descriptions must include the unit. |
Every tag must have a description following this format:
{Equipment full name} {measurement} in {unit}
|
Examples:
When the user asks to add tags for a pump, create this standard set:
{
"table_type": "UnsTags",
"data": [
{ "Name": "{Site}/{Unit}/Pump{N}/Status", "DataType": "Integer", "Description": "{Unit} Pump {N} status (0=Off, 1=Running, 2=Fault)" },
{ "Name": "{Site}/{Unit}/Pump{N}/Speed", "DataType": "Double", "Description": "{Unit} Pump {N} speed in RPM" },
{ "Name": "{Site}/{Unit}/Pump{N}/DischargePressure", "DataType": "Double", "Description": "{Unit} Pump {N} discharge pressure in PSI" },
{ "Name": "{Site}/{Unit}/Pump{N}/SuctionPressure", "DataType": "Double", "Description": "{Unit} Pump {N} suction pressure in PSI" },
{ "Name": "{Site}/{Unit}/Pump{N}/Flow", "DataType": "Double", "Description": "{Unit} Pump {N} flow rate in GPM" },
{ "Name": "{Site}/{Unit}/Pump{N}/BearingTemp", "DataType": "Double", "Description": "{Unit} Pump {N} bearing temperature in °F" },
{ "Name": "{Site}/{Unit}/Pump{N}/RunHours", "DataType": "Double", "Description": "{Unit} Pump {N} cumulative run hours" },
{ "Name": "{Site}/{Unit}/Pump{N}/StartCommand", "DataType": "Boolean", "Description": "{Unit} Pump {N} start command" },
{ "Name": "{Site}/{Unit}/Pump{N}/StopCommand", "DataType": "Boolean", "Description": "{Unit} Pump {N} stop command" }
]
}
|
Ask the user for Site, Unit, and pump number, then substitute into the template.
Alarm items follow this pattern:
{Site}_{Unit}_{Equipment}_{Condition}
|
Example: Houston_Distillation_Column1_TempHigh
After creating tags, verify: